BLJGZ - 5-MINUTE EPOXY RESIN

  • MSDS: BLJGZ
  • Manufacturer: ITW DEVCON CORP
  • Product Name: 5-MINUTE EPOXY RESIN
  • National Stock Number: 8040-00-264-6816
Product Identification

Product ID:5-MINUTE EPOXY RESIN
MSDS Date:12/14/1989
FSC:8040
NIIN:00-264-6816
MSDS Number: BLJGZ

Responsible Party
ITW DEVCON CORP
30 ENDICOTT ST
DANVERS, MA 01923
US

Emergency Phone: 800-424-9300 CHEMTREC

Info Phone: 508-777-1100

Cage: EO352

Contractor
ITW DEVCON CORP
DANVERS, MA 01923 US

Telephone: 508-777-1100

Cage: EO352

Ingredients

BISPHENOL A DIGLYCIDYL ETHER RESIN (POTENTIAL SKIN

CAS: 25068-38-6

RTECS: KD4380000

Fraction By Weight: >60%


0 LBS/GAL (EPA REFERENCE METHOD 24)

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:ORAL LD50 RAT: 11,400 MG/KG; DERM LD50 *
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PROLONGED OR REPEATED SKIN CONTACT MAY
CAUSE SENSITIZATION WITH ITCHING, SWELLING OR RASHES ON LATER
EXPOSURE.
Explanation of Carcinogenicity:*RABB: >20,000 MG/KG; INHALATION LC50
RAT: NO DEATHS IN SATURATED AIR; EXPOSURE TIME: 8 HRS.
Effects of Overexposure:EYES: MILD IRRITATION. SKIN: MILD IRRITATION.
INHALATION. THE LOW VAPOR PRESSURE OF THE RESIN MAKES INHALATION
UNLIKELY IN NORMAL USE. INGESTION: ACUTE ORAL TOXICITY IS LOW. MAY
CAUSE GASTRIC DISTRESS .
Medical Cond Aggravated by Exposure:ALLERGIES, ECZEMA OR OTHER SKIN
DISORDERS.

First Aid

First Aid:EYES: FLUSH W/CLEAN WATER-15 MIN. WHILE GENTLY HOLDING
EYELIDS OPEN. GET IMMED MEDICAL ATTENTION. SKIN: WASH THOROUGHLY
W/SOAP & WARM WATER. CONSULT PHYSICIAN IF IRRIT DEVELOPS.
INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS
DIFFICULT. GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. INGESTION: DO
NOT INDUCE VOMITING. GIVE 2 GLASSES WATER TO DILUTE (UNLESS
UNCONSCIOUS). GET MEDICAL ATTEN.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>400F,>204C
Lower Limits:N/D
Upper Limits:N/D
Extinguishing Media:CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SELF-CONTAINED
BREATHING APPARATUS AND PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:PREVENT SKIN AND EYE CONTACT. LARGE SPILLS MAY
BE ABSORBED ON INERT MATERIAL SUCH AS SAND OR VERMICULITE. SCRAPE
SPILL UP INTO NONPOROUS CONTAINERS. CLEAN SPILL AREA WITH STRONG
DETERGENT AND WATER; U SE SOLVENTS ONLY WITH APPROPRIATE CAUTION.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. HANDLE
MIXED RESIN & HARDENER IN ACCORDANCE W/POTENTIAL HAZARD OF THE
CURING AGENT USED. DISCARD CONTAM LEATHER ARTICLES.
Other Precautions:REMOVE CONTAMINATED CLOTHING AND PROTECTIVE GEAR;
CLEAN THOROUGHLY BEFORE USING AGAIN. IF CURED MATERIAL IS SANDED OR
MACHINED, USE ADEQUATE PRECAUTIONS AGAINST NUISANCE PARTICULATES.

Exposure Controls

Respiratory Protection:NONE REQUIRED AT NORMAL HANDLING TEMPERATURES.
Ventilation:LOCAL EXHAUST IS RECOMMENDED FOR CONFINED AREAS. GENERAL
MECHANICAL VENTILATION IS ADEQUATE FOR NORMAL USE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:OTHER GEAR AS REQUIRED.
Work Hygienic Practices:WASH THOROUGHLY AFTER USING, PARTICULARLY
BEFORE EATING OR SMOKING.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:N/D
Melt/Freeze Pt:M.P/F.P Text:N/D
Vapor Pres:NIL @ 70 F
Vapor Density:>1
Spec Gravity:1.2
pH:7 (5%)
Evaporation Rate & Reference:<<1 (BUAC = 1)
Solubility in Water:NIL
Appearance and Odor:THICK, AMBER LIQUID WITH LITTLE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS AND STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAME AND EXTREME HEAT.
Hazardous Decomposition Products:OXIDES OF CARBON, ALDEHYDES AND ACIDS
FROM INCOMPLETE COMBUSTION.
Conditions to Avoid Polymerization:HEAT IS GENERATED WHEN THIS RESIN IS
MIXED WITH AMINES OR EPOXY HARDENERS; BE CAREFUL WHEN MIXING.

Disposal

Waste Disposal Methods:REMOVE TO A WASTE FACILITY OPERATING IN
COMPLIANCE WITH STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.